Test Code VBG Venous Blood Gas
Performing Laboratory
Hunterdon Medical Center Laboratory
Test Includes
Venous Analytes
Measured | Calculated |
pH | Base excess |
pCO₂ | Bicarbonate (HCO₃) |
pO₂ | Total CO₂ |
O₂ Saturation |
Special Instructions
Note: Effective March 1, 2016, specimen must be received on ice. Place specimen in plastic bag and close; then place in a bag of ice. Deliver to the Laboratory immediately after collection.
Specimen Required
Container/Tube: Blood Gas Syringe or Heparinized Green Top Tube.
Specimen Volume: 1ml
Minimum Specimen Volume: 0.5ml
Specimen Type
Venous blood
Specimen Transport Temperature
Deliver on ice.
Reject Specimen Due To
Clotted
Quantity Not Sufficient for testing
Day(s) Test Set up
Monday through Sunday
Available STAT
Reference Values
Venous Analytes
Test | Reference Value | Units |
pH | 7.320 -7.430 | |
pCO2 | 40.0 – 60.0 | mm[Hg] |
pO₂ | 30.0 – 55.0 | mm[Hg] |
Bicarbonate (HCO₃) | 22.0 – 27.0 | mmol/L |
Total CO₂ | 40.0 – 45.0 | mmol/L |
Base Excess | -2.0 to 2.0 | mmol/L |
O₂ Saturation | 40.0 – 85.0 | % |
Methodology
Visible absorption spectroscopy
CPT Code
82083
Loinc Code
Test | LOINC |
pH | 2746-6 |
pCO₂ | 2021-4 |
pO2 | 2703-7 |
pO2 | 2705-2 |
Base Excess | 1927-3 |
Bicarbonate (HCO3) | 14627-4 |
Total CO2 | 2027-1 |
O2 Saturation | 2711-0 |