Test Code TS Type and Screen (Blood Bank)
Performing Laboratory
Hunterdon Medical Center Laboratory
Test Includes
ABO Rh and Antibody Screen
Special Instructions
Note: All Blood Bank specimens must be correctly labeled or the specimen must be rejected. Specimens must be labeled at the patient's bedside.
Pre-printed label is preferred. Label must contain the patient's complete name and medical record number. Collector's initials and date of draw must be recorded on the label.
Blood Bank Request, completed and signed, must accompany the specimen.
If no pre-printed label is available the following must be written in ink on the tube: patient’s complete name and medical record number. Collector's initials and date of draw must be recorded on the label.
Blood Bank Request, completed and signed, must accompany the specimen.
Specimen Required
Container/Tube: Pink-top EDTA
Specimen Volume: 6ml
Minimum Specimen Volume: Full Tube
Specimen Type
Whole Blood
Specimen Transport Temperature
Ambient
Specimen Stability Information
Refrigerate 2-8°C:14 days
Reject Due To
Improperly labeled specimen
Day(s) Test Set Up
Monday through Sunday
Available STAT
Reference Values
Not applicable
CPT Code
86900-ABO
86901-Rh
86850-Type and Screen
Loinc Code
34532-2