Test Code TRTWD Troponin-T High Sensitivity with Delta
Performing Laboratory
Hunterdon Medical Center
Useful For
High sensitivity Cardiac Troponin T (cTnT) is useful for monitoring acute coronary syndromes including myocardial infarction and is associated with an improved rule-out process.
To distinguish between acute and chronic cardiac troponin elevation a High Sensitivuty Troponin with Delta (TRTWD) may be ordered two to three hours following the initial Troponin T test, at the discretion of the ordering physician. Serial testing is available only for ED patients.
A serial Troponin test is collected and the subsequent results are compared to the baseline test and the delta change is calculated.
Specimen Requirements
| Container/Tube | |
| Preferred | PST (Li Hep) Gel- Mint Green Top |
| Acceptable | Green Top |
| Specimen Volume | 1.0mL |
| Minimum Volume | 0.5mL |
Specimen Type
Lithium Heparin Plasma
Specimen Transport
Ambient
Specimen Stability
| Temperature | Time Frame |
| Refrigerated 2-8°C | 24 hours |
Reject Specimen Due To
Gross hemolysis
Day(s) Test Set up
Monday through Sunday
Profile Information
| Profile Components | Always Performed |
| Troponin-T HS, Subsequent | Yes |
| Troponin-T HS, Baseline | Baseline Result |
| Delta | Yes |
Reference Values
| Reference Values | * Note difference in units |
| Female | ≤ 14ng/L* |
| Male | ≤ 22ng/L* |
| Critical Value | >52 ng/L* |
| Indeterminate Range | |
| Female | 15-52 ng/L |
| Male | 23-52 ng/L |
| Troponin is moderately elevated but does not confirm myocardial injury | |
| Delta | |
| Reference Value | 0-6 ng/L |
| Interpretation | Rule in possible AMI if delta change is >9ng/L, in conjunction with other clinical parameters. |
Methodology
Electrichemiluminescence Immunoassay: ELCIA
CPT Code
84484
Loinc Code
67151-1