Sign in →

Test Code LEGAB Legionella pneumophila (Legionnaires Disease), Antibody, Serum

Reporting Name

Legionella Pneumophila Ab, S

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Useful For

Evaluating possible legionellosis (Legionnaires disease, Pontiac fever, extrapulmonary legionella infection caused by Legionella pneumophila)


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Specimen Minimum Volume

0.4 mL

Specimen Type

Serum

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 14 days
  Frozen  14 days

Day(s) Performed

Wednesday

Reference Values

Negative

Reference values apply to all ages.

Method Name

Enzyme-Linked Immunosorbent Assay (ELISA)

Test Classification

This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.

CPT Code Information

86713

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SLEG Legionella Pneumophila Ab, S 7947-5

 

Result ID Test Result Name Result LOINC Value
SLEG Legionella Pneumophila Ab, S 7947-5

Report Available

1 to 7 days

Forms

If not ordering electronically, complete, print, and send Infectious Disease Serology Test Request (T916) with the specimen.