Sign in →

Test Code HBSB Hepatitis B Surface Antibody, Qualitative/Quantitative

Performing Laboratory

Hunterdon Medical Center

Useful For

Determining immunity following hepatitis B vaccination.

Identifying previous exposure to hepatitis B virus.

Specimen Requirements

 

Container/Tube  
Preferred SST
Acceptable Red Top
Specimen Volume  1.0 mL
Minimum Volume  0.5 mL

 

Specimen Type

Serum

Specimen Transport Temperature

Refrigerated 2-8°C

 

Specimen Stability

 

Temperature Time Frame
Refrigerated 2-8°C 6 days

Day(s) Test Set up

Monday through Friday

Reference Values

 

Result Quantitative Result Immune Status
Reactive >9.9 m[IU]/mL Immune (Reactive)
Non-Reactive <10 m[IU]/mL Not Immune (Non-reactive)

Methodology

Electrichemiluminescence Immunoassay: ECLIA

CPT Code

86706

Loinc Code

 

Test LOINC
HBSB Quantitative 22322-2
HBSB Interpretation 16935-9