Test Code DAIP Diabetes Autoimmune Profile
Reporting Name
Diabetes Autoimmune ProfilePerforming Laboratory
Esoterix EndocrinologyUseful For
Diabetes autoantibodies assessment is helpful in identifying and managing patients at risk for development of type 1 diabetes.
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/tube: Plastic vial
Specimen Volume: 2.5 mL
Collection Instructions:
1. Within 24 hours of collection, centrifuge and aliquot 2.5 mL of serum into a plastic vial.
2. Freeze within 24 hours and send frozen.
Specimen Minimum Volume
1 mL (Note: This volume does not allow for repeat testing)
Specimen Type
SerumSpecimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Frozen | 7 days |
Day(s) Performed
Varies
Report Available
10 to 19 daysReference Values
Insulin Antibodies
<5.0 uU/mL: Negative
≥5.0 uU/mL: Positive
Anti GAD 65 Antibodies
<5.0 U/mL: Negative
≥5.0 U/mL: Positive
IA-2 Autoantibodies
<7.5 U/mL: Negative
≥7.5 U/mL: Positive
ZNT8 Antibodies
<15 U/mL: Negative
≥15 U/mL: Positive
Reference ranges apply to all ages.
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA), Radioimmunoprecipitation
Test Classification
Insulin Antibodies: This test was developed and its performance characteristics determined by LabCorp. It has not been cleared or approved by the Food and Drug Administration.CPT Code Information
86337
86341x3
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| FDAIP | Diabetes Autoimmune Profile | Not Provided |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| Z6377 | Insulin Antibodies | 8072-1 |
| Z6378 | Anti GAD 65 Antibodies | 56540-8 |
| Z6387 | IA-2 Autoantibodies | 31209-0 |
| Z6388 | ZNT8 Antibodies | 76651-9 |
| Z6389 | Type 1 Diabetes Interpretation | 8251-1 |