Test Code ANTIGA (SoftLab Z2145) Anti-IgA
Reporting Name
Anti-IgAPerforming Laboratory
Eurofins ViracorSpecimen Required
Specimen Type: Serum
Container/Tube: Red or SST
Specimen Volume: 1 mL
Collection Instructions: Draw blood in a plain, red-top tube(s) or serum gel tube(s). Spin down and send 1 mL of serum refrigerate in a plastic vial.
Specimen Minimum Volume
0.5 mL
Specimen Type
SerumSpecimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 7 days | |
Frozen | 30 days | ||
Ambient | 7 days |
Day(s) Performed
Thursday
Reference Values
<99 U/mL
Patients with IgG antibodies against IgA may suffer from anaphylactoid reactions when given IVIG that contains small quantities of IgA. In one study (Clinical Immunology 2007; 122:156) five out of eight patients with IgG anti-IgA antibodies developed anaphylactoid reactions when IVIG was administered.
Method Name
Enzyme-Linked Immunosorbent Assay (ELISA)
Test Classification
This test was developed and its performance characteristics determined by Viracor Eurofins. It has not been cleared or approved by the U.S. Food and Drug Administration.CPT Code Information
83520
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
FIGA | Anti-IgA | 13312-4 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
FIGA | Anti-IgA | 13312-4 |